Test/IT/Medical/Lab Equipment
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-K
- R:SS trans+SS long-neck remote: stainless steel housing stainless steel terminal housing long neck
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-JS
- IOp, NamPLp, IOp, NamPLp 1 passive current output HART, 2 passive Namur pulse or status output, 1 passive current output
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-JR
- IOp, NamPLp, IOp, 1 passive current output HART, 1 passive Namur pulse or status output, 1 passive current output
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-JQ
- IOp, PLp, IOp, PLp 1 passive current output HART, 2 passive pulse output or status output, 1 passive current output
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-JP
- IOp, PLp, IOp 1 passive current output HART, 1 passive pulse output or status output, 1 passive current output,
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-JG
- IOa, PLp, DI, PLa 1 active current out HART, 1 passive pulse or status out, 1 active pulse or status out, 1 voltage-free digital input
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-JF
- IOa, PLp, DI, PLa pull-up 1 active current out HART, 1 passive pulse or statusout,1active pull-up pulse or statusout,1voltage-free digital input
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-JE
- IOa, PLp, DI, PLp 1 active current output HART 2 passive pulse output or status output 1 voltage-free digital input
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-JD
- IOa, PLp,STp, PLp 1 active current output HART 2 passive pulse output or status output 1 passive status output
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-JC
- IOa, PLp, DI, IOa 2 active current output HART 1 passive pulse output or status output 1 voltage-free digital input
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-JB
- IOa, PLp, PLp, IOa 2 active current output HART 2 passive pulse output or status output
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-J
- R:SS trans+SS std-neck remote: stainless steel housing stainless steel terminal housing standard neck
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-H1
- Degreasing wetted surfaces Degreasing of wetted surfaces acc. ASTM G93/G93M-19, level C, test report
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-FF12
- FM XP tra+IS sen CDEFG FM approval for USA and Canada explosionproof transmitter and intrinsic safe sensor (GP CDEFG)
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-FF11
- FM XP tra+IS sen ABCDEFG FM approval for USA and Canada explosionproof transmitter and intrinsic safe sensor (GP ABCDEFG)
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-F
- R:AL corr paint+SS long-neck remote: low copper aluminium housing corrosion protection coating SS terminal housing long neck
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-E
- R:AL corr paint+ std-neck remote: low copper aluminium housing corrosion protection coating SS terminal housing standard neck
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-B
- R:AL UP+SS long-neck remote: low copper aluminium housing urethane-cured polyester powder coating SS terminal housing long neck
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-A
- R:AL UP+SS std-neck remote: low copper aluminium housing urethane-cured polyester powder coating SS terminal housing standard neck
|
|
|
|
*
|
|
|
Yokogawa RCEG2HS-3
- high temperature process fluid temperature range remote: 0 to 350°C (32 to 662 °F)
|
|
|
|